Failure mechanisms & evidence
What a change may mean - and what to do next.
Each signal is an investigative cue. Limits must be chosen for the actual lubricant, machine, operating state and sensor method; a single reading rarely proves a root cause.
FLOW
Low level, pressure or flow
Could indicate: leakage, empty reservoir, stalled pump, restriction, blocked filter or loss of prime.
Next: inspect the circuit and filter, verify pump delivery, repair the cause and confirm readings after the work.
VISC
Viscosity or density departs
Could indicate: wrong or mixed oil, ageing, shear, dilution or another composition change. Temperature strongly affects interpretation.
Next: compare with the oil-specific reference at a known temperature; check service history and confirm with a suitable sample test.
H₂O
Water saturation rises
Could indicate: condensation, seal or breather ingress, or a leaking cooler/heat exchanger. Water can undermine lubrication and contribute to corrosion.
Next: inspect ingress paths, trend with temperature and confirm absolute water content with an appropriate laboratory method if needed.
ISO
Particle cleanliness worsens
Could indicate: dirt ingress, poor oil handling, filter bypass/failure or generated wear debris. Hydraulic pumps and valves may be sensitive to contamination.
Next: compare with the machine's cleanliness target; inspect filtration and breathers, then trend after corrective action.
Fe
Wear-debris trend increases
Could indicate: active wear in a ferrous component or a contamination event. A basic particle count does not identify the particle or failed component.
Next: correlate with vibration and operating history; take a representative sample and involve a reliability or oil-analysis specialist.
AGE
Ageing or oxidation indicators change
Could indicate: thermal stress, oxidation, contamination or additive depletion; a dielectric reading is an application-specific proxy, not a universal oil-life meter.
Next: review temperature and duty trends; validate the proxy against periodic laboratory results before setting action limits.
Density alone is not an oil-health diagnosis. It needs temperature context and an oil-specific reference.